Mircom Fire Alarm System
Mircom Fire Alarm System
• Listed to UL 864, 9th edition
• 8 Class B (Style B) Initiating Circuits, configured as 4 Class A (Style D) Circuits.
• Expandable up to 24 Class B or 12 Class A Initiating Circuits
• 4 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators.
• Each Indicating Circuit can be configured as Silenceable or Non-Silenceable.
• Each Initiating Circuit can be configured as • Alarm, Supervisory, Waterflow or Trouble
• Two LEDs per Initiating circuit
• Initiating and Indicating Circuits may be individually disconnected
• Configurable Signal Silence Inhibit, Auto Signal, Silence, Two-Stage Operation and One Man Walk Test
• Alarm Verification on Initiating Circuits
• Subsequent Alarm, Supervisory and Trouble operation
• Two outputs for 4 wire resettable smoke power supply
• Auxiliary relay contacts for Common Alarm and Common Supervisory
• RS-485 Interface for RA-1000 Remote Multiplex Annunciators
• Interface for Remote Trouble Indicator
• Easy configuration via push buttons and DIP switches on the front panel
• Extensive Transient Protection
• 6 Amp Power Supply
• Removable door for easy installation and servicing

• Listed to UL 864, 9th edition
• 8 Class B (Style B) Initiating Circuits, configured as 4 Class A (Style D) Circuits.
• Expandable up to 24 Class B or 12 Class A Initiating Circuits
• 4 Class A/B (Style Z/Y) Indicating Circuits with individual trouble indicators.
• Each Indicating Circuit can be configured as Silenceable or Non-Silenceable.
• Each Initiating Circuit can be configured as • Alarm, Supervisory, Waterflow or Trouble
• Two LEDs per Initiating circuit
• Initiating and Indicating Circuits may be individually disconnected
• Configurable Signal Silence Inhibit, Auto Signal, Silence, Two-Stage Operation and One Man Walk Test
• Alarm Verification on Initiating Circuits
• Subsequent Alarm, Supervisory and Trouble operation
• Two outputs for 4 wire resettable smoke power supply
• Auxiliary relay contacts for Common Alarm and Common Supervisory
• RS-485 Interface for RA-1000 Remote Multiplex Annunciators
• Interface for Remote Trouble Indicator
• Easy configuration via push buttons and DIP switches on the front panel
• Extensive Transient Protection
• 6 Amp Power Supply
• Removable door for easy installation and servicing

NetworX NX-4/6/8 Control panel | Fire Alarm Call Point | Alarm Bells system | Mechanical Heat Detector |
![]() | ![]() | ![]() | ![]() |
View:255 | View:255 | View:255 | View:255 |
Plug-in Detector | Smoke Detector | Heat Dectetor | Smoke Detector |
![]() | ![]() | ![]() | ![]() |
View:241 | View:243 | View:255 | View:255 |
Alarm Control Panel | Security Products | Fire Detection Products | Mircom Fire Alarm Control Panel |
![]() | ![]() | ![]() | ![]() |
View:203 | View:255 | View:236 | View:255 |
Beam Smoke Detector - NITTAN | Smoke Detector Horing LIH AHS-871 | Smoke detector HOCHIKI | |
![]() | ![]() | ![]() | |
View:255 | View:253 | View:255 |
Main Menu
Salient Projects
Website Links
Information access
Online:4
Visit Times:76376
Visit Times:76376